AjiENG.com

Aji New Material (Qingdao) Co.,LTD

No.47 Huadingshan Road, Qingdao City, Shandong Province, China.
Tel: +86 532 86871530
Email: info@ajieng.com

Stanyl® TE250F6

PA46

Envalior

Product Description

30% Glass Fiber Reinforced, Flame Retardant

Stanyl® TE250F6 is an electro-friendly & flame-retarded high heat polyamide that offers excellent creep resistance, strength, stiffness and fatigue resistance especially at high temperatures in combination with cycle-time advantages and excellent flow.

General
Original Document
Technical Datasheet(English)
Resin ID
PA46-GF30 FR(17)
Features
Fatigue Resistant
Heat Resistance
Flame Retardant
Creep Resistant
Good Flow
Filled & Reinforced
Additive
Flame Retardant
Processing
Injection
Automotive Specs
FORD WSK-M4D715-A
Diagrams
Stress-strain
Stress-strain (Cond.)
Secant modulus-strain
Secant modulus-strain (Cond.)
Stress-strain (isochronous)(Creep) 23°C
Creep modulus-time 23°C
Dynamic Shear modulus-temperature
Specific volume-temperature (pvT)
Dynamic Shear modulus (G storage)-temperature
Viscosity-shear rate
Shearstress-shear rate
Reinforced
30% Glass Fiber
Specifications
Physical Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Density/Specific Gravity

***/ *** g/cm³ ISO 1183

Mold Shrinkage

Flow

***/ * % ISO 294-4

Across Flow

***/ * % ISO 294-4

Water Absorption

***/ * % ISO 62

Water Absorption

***/ * % ISO 62
in water at 23°C after 24h

Moisture /Humidity Absorption

***/ * % ISO 62

Viscosity

***/ * cm³/g ISO 307, 1157, 1628

Melt Density

***/ * g/cm³ -

Spiral Flow

***/ * mm -
0.5mm 1200 bar

Spiral Flow

***/ * mm -
0.5mm 1600 bar

Spiral Flow

***/ * mm -
0.5mm 2000 bar

Spiral Flow

***/ * mm -
1.0 mm 1000 bar

Spiral Flow

***/ * mm -
1.0 mm 800 bar

Spiral Flow

***/ * mm -
1.0 mm 900 bar
Mechanical Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Tensile Modulus

***/ *** Mpa ISO 527-1/-2

Tensile Modulus

***/ *** Mpa ISO 527-1/-2
120°C

Tensile Modulus

***/ * Mpa ISO 527-1/-2
160°C

Tensile Modulus

***/ *** Mpa ISO 527-1/-2
1mm Thickness

Tensile Strength

Break

***/ *** Mpa ISO 527-1/-2

Break

***/ *** Mpa ISO 527-1/-2
120°C

Break

***/ * Mpa ISO 527-1/-2
160°C

Break

***/ *** Mpa ISO 527-1/-2
1mm Thickness

Tensile Elongation

Break

***/ *** % ISO 527-1/-2

Break

***/ *** % ISO 527-1/-2
120°C

Break

***/ * % ISO 527-1/-2
160°C

Break

***/ *** % ISO 527-1/-2
1mm Thickness

Flexural Modulus

***/ *** Mpa ISO 178

Flexural Modulus

***/ * Mpa ISO 178
120°C

Flexural Modulus

***/ * Mpa ISO 178
160°C

Flexural Strength

-

***/ *** Mpa ISO 178

-

***/ * Mpa ISO 178
120°C

-

***/ * Mpa ISO 178
160°C

Weld strength

***/ *** Mpa ISO 527-1/-2
1mm

Weld strength

***/ *** Mpa ISO 527-1/-2
4mm

Weld elongation

***/ *** % ISO 527-1/-2
1mm

Weld elongation

***/ *** % ISO 527-1/-2
4mm
Impact Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Charpy Notched Impact Strengh

-30℃ (-22℉)

***/ *** kJ/m² ISO 179/1eA

23℃ (73℉)

***/ *** kJ/m² ISO 179/1eA

Charpy Unnotched Impact Strengh

-30℃ (-22℉)

***/ *** kJ/m² ISO 179/1eU

23℃ (73℉)

***/ *** kJ/m² ISO 179/1eU

Izod Notched Impact Strengh

-40℃ (-40℉)

***/ *** kJ/m² ISO 180/1A

23℃ (73℉)

***/ *** kJ/m² ISO 180/1A
Thermal Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Heat Deflection Temperature(HDT)

0.45 Mpa (66 psi)(4.6kg/cm²)

***/ * °C ISO 75-1/-2

1.8 Mpa (264 psi)(18.6kg/cm²)

***/ * °C ISO 75-1/-2

Vicat Softening Temperature(VST)

***/ * °C ISO 306/B50
50°C/h 50N

Relative Temperature Index(RTI), Imp

0.75/0.8mm

***/ * °C UL 746B

3.0/3.2 mm

***/ * °C UL 746B

Relative Temperature Index(RTI), Elec

0.75/0.8mm

***/ * °C UL 746B

3.0/3.2 mm

***/ * °C UL 746B

Relative Temperature Index(RTI), Str

0.75/0.8mm

***/ * °C UL 746B

3.0/3.2 mm

***/ * °C UL 746B

Specific Heat

***/ * J/kg-K -
melt

Coefficient of Linear Thermal Expansion

Flow

***/ * E-6/°C ISO 11359-1/-2

Flow

***/ * E-6/°C ASTM D 696

Across Flow

***/ * E-6/°C ISO 11359-1/-2

Across Flow

***/ * E-6/°C ASTM D 696

Melt Temperature(Tm)

***/ * °C ISO 11357-1/-3
10°C/min

Glass Transition Temperature

***/ * °C ISO 11357-1/-2
10°C/min

Thermal Conductivity

***/ * W/(m K) -
melt

Thermal Diffusivity

***/ * m²/s -

Ball Pressure Test

***/ * °C IEC 60695-10-2

Temperature index (TI)-Tensile Strength

2500 h

***/ * °C IEC 60216

5000 h

***/ * °C IEC 60216

10000 h

***/ * °C IEC 60216

20000 h

***/ * °C IEC 60216
Flammability Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Flame Rating

V-0

***/ * mm UL94

V-0

***/ * mm UL94

V-0

***/ * mm UL94

V-0

***/ * mm IEC 60695-11-10

V-0

***/ * mm IEC 60695-11-10

V-0

***/ * mm IEC 60695-11-10

Oxygen Index

***/ * % ISO 4589-1/-2

Glow Wire Flammability Index(GWFI)

0.75mm

***/ * °C IEC 60695-2-12

3mm

***/ * °C IEC 60695-2-12

Glow Wire Ignition Test(GWIT)

0.75mm

***/ * °C IEC 60695-2-13

3.0mm

***/ * °C IEC 60695-2-13
Electrical Dry/Cond.(Sign in to View) Unit Test Standard Test Condition

Volume Resistivity

***/ *** Ohm-m IEC 62631-3-1

Dielectric Constant(Permittivity)

100Hz

***/ *** - IEC 62631-2-1

1MHz

***/ *** - IEC 62631-2-1

1 GHz

***/ *** - IEC 61189-2-721

Dissipation Factor

100Hz

***/ *** E-4 IEC 62631-2-1

1MHz

***/ *** E-4 IEC 62631-2-1

1 GHz

***/ *** E-4 IEC 61189-2-721

Comparative Tracking Index (CTI)

-

***/ *** V IEC 60112

Dielectric Strength

***/ *** kV/mm IEC 60243-1

The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.