AjiENG.com

Aji New Material (Qingdao) Co.,LTD

No.47 Huadingshan Road, Qingdao City, Shandong Province, China.
Tel: +86 532 86871530
Email: info@ajieng.com

Tufnol Grade PGM/2

Polyester,TP

Tufnol

Product Description

Polyester glass mat laminates. 

 

TUFNOL Polyester glass mat laminates are produced by combining polyester resin with continu-ous roving glass mat. They are a useful group of materials that fall in price and performance between paper and cotton fabric laminates and high performance woven glass types. 

Two grades are available, offering compliance with NEMA Types GPO-2, NEMA GPO-3 and DIN 7735 Type Hm 2471.  These materials have excellent mechanical and electrical properties and are widely used in applications where good electrical insulation is required up to thermal class F temperatures (155°C). 

 

TUFNOL PGM Grades. 

 Grade PGM/2 An electrical grade with assessed flammabiltiy characteristics (UL 94 V-0). Good for cold punch-ing. Colour ivory. NEMA Type GPO-2. Suitable for thermal class F applications. Available in sheets from 0.8mm to 25mm thick. 

 Grade PGM/3 An electrical grade with assessed flammability characteristics (UL 94 V0) plus excellent arc and track resistance.  Colour red.  NEMA Type GPO-3 and DIN 7735 Type 2471. Suitable for thermal class F applications.  Available in sheets from 0.8mm to 25mm thick.

General
Original Document
Technical Datasheet(English)
Appearance
Sheet
Ivory
Reinforced
Glass Fabric
Specifications
Physical Value/Unit(Sign in to View) Test Standard Test Condition

Density/Specific Gravity

*** g/cm³ Internal

Water Absorption

*** % -
3mm thk.
Mechanical Value/Unit(Sign in to View) Test Standard Test Condition

Tensile Modulus

*** Mpa Internal

Tensile Strength

-

*** Mpa Internal

Flexural Modulus

*** Mpa Internal

Flexural Strength

-

*** Mpa Internal
Impact Value/Unit(Sign in to View) Test Standard Test Condition

Charpy Notched Impact Strengh

-

*** kJ/m² Internal
Thermal Value/Unit(Sign in to View) Test Standard Test Condition

Coefficient of Linear Thermal Expansion

-

*** E-6/K Internal

Thermal Conductivity

*** W/(m K) -

Continuous Use Temperature

Long term

*** °C Internal

Temperature at Short Circle Operation

*** °C Internal
Flammability Value/Unit(Sign in to View) Test Standard Test Condition

Flame Rating

V-0

*** mm UL94
Electrical Value/Unit(Sign in to View) Test Standard Test Condition

Comparative Tracking Index (CTI)

-

*** V IEC 60112

Dielectric Strength

*** kV/mm Internal
Perpendicular dielectric strength

Breakdown Voltage

*** V ASTM D149
parallel to laminations

The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.