Specifically formulated for low-pressure applications requiring a low sealing force, Chemraz® 504 is recommended for a wide variety of medical and biotechnology device applications requiring long-term seal reliability. Chemraz 504 offers excellent performance in dynamic and static analytical equipment applications where slight lubrication is preferred to lower friction. Chemraz 504 is suitable for service temperatures ranging from 0°F to 400°F (-18°C to 204°C).
FEATURES & BEN EEITS
Excellent performance under low pressure and low sealing force
Lubricated compound to minimize friction
Dependable balance of physical properties
Good chemical resistance
APPLICATIONS
Analytical lnstrumentation—Gaskets and O-rings
Solenoid \/alves—Plunger seals, gaskets and O-rings
| Original Document | Technical Datasheet(English) | |||
| Features | Wear/Abrasion ResistanceLow Friction/WearLubricatedChemical Resistance | |||
| Appearance | Black | |||
| Physical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
|---|---|---|---|
Density/Specific Gravity | *** g/cm³ | ASTM D297 | |
| Mechanical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Tensile Strength | |||
- | *** Mpa | ASTM D1414 | |
at 50% strain | *** Mpa | ASTM D1414 | |
at 100% strain | *** Mpa | ASTM D1414 | |
Tensile Elongation | |||
- | *** % | ASTM D1414 | |
Compression Set | *** % | ASTM D 395 | 204°C, 70 hr, 25% Deflection |
| Hardness | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Shore A hardness | *** A | ASTM D 2240 | |
| Thermal | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Continuous Use Temperature | |||
Long term | ***~*** °C | Internal |
The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.