DuPont™ Kapton® FWR is a heat fusible polyimide-FEP fluoropolymer composite film that has a unique balance of excellent electrical, thermal durability, and chemical resistance properties. The properties of Kapton® FWR will provide a tough, high dielectric strength insulation with significantly improved hydrolysis resistance compared to other commonly used polyimide materials.
Kapton® FWR can be properly processed on most tape wrapping machines. It can be fused using either induction or radiant heat. Kapton® FWR films have a higher modulus and lower water vapor permeability than equivalent Kapton® FN films. The wire wrapping and sealing process may have to be modified to compensate for these differences.
Kapton® 150FWR019 film is constructed of a 1.0 mil Kapton® polyimide film with 0.5 mil of FEP fluoropolymer on one side. Kapton® 200FWR919 film is constructed of a 1.0 mil Kapton® polyimide film with 0.5 mil of FEP fluoropolymer on each side.
Characteristics
• Excellent hydrolysis resistance • UL 94 recognition: V-0 • High dielectric strength • Mechanically Tough • Heat Fusible
Applications
• Magnet wire • Traction motors: rail, auto, mining • Industrial motor insulation • Wind, hydro generators • ESP motors • High temperature • High reliability • Aerospace and specialty wires
| Original Document | Technical Datasheet(English) | |||
| Appearance | Film | |||
| Physical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
|---|---|---|---|
Density/Specific Gravity | *** g/cm³ | ASTM D 1505 | 38 µm |
Water Absorption | *** % | ASTM D570 | 100% RH |
| Thermal | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Relative Temperature Index(RTI), Elec | |||
- | *** °C | UL 746B | 38 µm |
Relative Temperature Index(RTI), Str | |||
- | *** °C | UL 746B | 38 µm |
| Flammability | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Flame Rating | |||
V-0 | *** mm | UL94 | 38 µm |
| Electrical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Volume Resistivity | *** Ohm-cm | ASTM D257 | 38 µm |
Dielectric Constant(Permittivity) | |||
1 kHz | *** - | ASTM D 150 | 38 µm |
Dissipation Factor | |||
1 kHz | *** E-4 | ASTM D 150 | 38 µm |
Dielectric Strength | *** kV/mm | ASTM D149 | 38 µm |
| Film | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Tensile Strength | |||
- | *** Mpa | ASTM D882 | 38 µm |
Tensile Elongation | |||
- | *** % | ASTM D882 | 38 µm |
Tensile Modulus | *** Mpa | ASTM D 882 | 38 µm |
Water Vapor Transmission Rate | *** g/m²/24 hr | ASTM E96 | |
Yield Factor | *** m²/kg | Internal | 38 µm |
The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.