Vydyne 21SPF is a general-purpose PA66 resin. Available in natural, it is designed principally for injection-molding fabrication. This grades offer a well-balanced combination of engineering properties characterized by high strength; rigidity; good toughness; high melt point; good surface lubricity; abrasion resistance and resistance to many chemicals, machine and motor oils, solvents and gasoline.
Vydyne 21SPF resin permits production of molded parts with good initial color plus good property and color retention when using regrind. This resin is recognized by Underwriters Laboratories and conforms to the requirements of many industrial, federal and military specifications for premium-quality, general-purpose PA66 resins.
Vydyne 21SPF resin is internally and externally lubricated for improved machine feed and exceptional mold release. It is intended for use in high-productivity applications. In many applications, the molding cycle can be reduced because parts may be removed from the cavity at higher temperatures. In difficult molds where parts have a tendency to stick in the cavity, Vydyne 21SPF can reduce or eliminate the need for mold release sprays. Critical molded part dimensions should be checked against specifications before implementing shorter molding cycles on a routine production basis.
| Original Document | Technical Datasheet(English) | |||
| Features | High StrengthHigh Stiffness/RigidityWear/Abrasion ResistanceFast Cycle TimeMold ReleaseChemical ResistanceFuels ResistantOil ResistantAnti-Solvent | |||
| Additive | Lubricant | |||
| Appearance | Pellets/GranulesNatural Color | |||
| Processing | Injection | |||
| Compliance | EU 2011/10/ECFDAFED L-P-410AMIL M-20693BRoHS | |||
| Physical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
|---|---|---|---|
Density/Specific Gravity | *** g/cm³ | ISO 1183 | |
Mold Shrinkage | |||
Flow | *** % | ISO 294-4 | 23°C, 2.00 mm |
Across Flow | *** % | ISO 294-4 | 23°C, 2.00 mm |
Outdoor Suitability UL F1/F2 | |||
F2 | *** - | UL 746C | All Colors |
Water Absorption | *** % | ISO 62 | 24 hr, 23°C |
Water Absorption | *** % | ISO 62 | Equilibrium, 23°C, 50% RH |
| Mechanical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Tensile Modulus | *** Mpa | ISO 527-2 | Conditioned, 23°C |
Tensile Modulus | *** Mpa | ISO 527-2 | Dry, 23°C |
Tensile Strength | |||
Yield | *** Mpa | ISO 527-2 | Conditioned, 23°C |
Yield | *** Mpa | ISO 527-2 | Dry, 23°C |
Break | *** Mpa | ISO 527-2 | Conditioned, 23°C |
Break | *** Mpa | ISO 527-2 | Dry, 23°C |
Tensile Elongation | |||
Yield | *** % | ISO 527-2 | Conditioned, 23°C |
Yield | *** % | ISO 527-2 | Dry, 23°C |
Nominal Tensile Strain at Break | *** % | ISO 527-2 | Conditioned, 23°C |
Nominal Tensile Strain at Break | *** % | ISO 527-2 | Dry, 23°C |
Flexural Modulus | *** Mpa | ISO 178 | Conditioned, 23°C |
Flexural Modulus | *** Mpa | ISO 178 | Dry, 23°C |
Flexural Strength | |||
- | *** Mpa | ISO 178 | Conditioned, 23°C |
- | *** Mpa | ISO 178 | Dry, 23°C |
Poisson Ratio | *** - | ISO 527-2 | Dry |
| Impact | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Charpy Notched Impact Strengh | |||
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eA | Conditioned |
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eA | Dry |
23℃ (73℉) | *** kJ/m² | ISO 179/1eA | Conditioned |
23℃ (73℉) | *** kJ/m² | ISO 179/1eA | Dry |
Charpy Unnotched Impact Strengh | |||
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eU | Conditioned |
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eU | Dry |
23℃ (73℉) | *** kJ/m² | ISO 179/1eU | Conditioned |
23℃ (73℉) | *** kJ/m² | ISO 179/1eU | Dry |
Izod Notched Impact Strengh | |||
-30℃ (-22℉) | *** kJ/m² | ISO 180 | Conditioned |
-30℃ (-22℉) | *** kJ/m² | ISO 180 | Dry |
23℃ (73℉) | *** kJ/m² | ISO 180 | Conditioned |
23℃ (73℉) | *** kJ/m² | ISO 180 | Dry |
| Thermal | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Heat Deflection Temperature(HDT) | |||
0.45 Mpa (66 psi)(4.6kg/cm²) | *** °C | ISO 75-2/B | Dry, Unannealed |
1.8 Mpa (264 psi)(18.6kg/cm²) | *** °C | ISO 75-2/A | Dry, Unannealed |
Relative Temperature Index(RTI), Imp | |||
0.36/0.4mm | *** °C | UL 746 | Dry |
0.71mm | *** °C | UL 746 | Dry |
1.5/1.6 mm | *** °C | UL 746 | Dry |
3.0/3.2 mm | *** °C | UL 746 | Dry |
Relative Temperature Index(RTI), Elec | |||
0.36/0.4mm | *** °C | UL 746 | Dry |
0.71mm | *** °C | UL 746 | Dry |
1.5/1.6 mm | *** °C | UL 746 | Dry |
3.0/3.2 mm | *** °C | UL 746 | Dry |
Relative Temperature Index(RTI), Str | |||
0.36/0.4mm | *** °C | UL 746 | Dry |
0.71mm | *** °C | UL 746 | Dry |
1.5/1.6 mm | *** °C | UL 746 | Dry |
3.0/3.2 mm | *** °C | UL 746 | Dry |
Coefficient of Linear Thermal Expansion | |||
Flow | *** E-6 cm/cm/℃ | ISO 11359-2 | Dry, 23 to 55°C, 2.00 mm |
Across Flow | *** E-6 cm/cm/℃ | ISO 11359-2 | Dry, 23 to 55°C, 2.00 mm |
Melt Temperature(Tm) | *** °C | ISO 11357-3 | Dry |
| Flammability | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Flame Rating | |||
V-2 | *** mm | UL94 | Dry |
V-2 | *** mm | UL94 | Dry |
V-2 | *** mm | UL94 | Dry |
V-2 | *** mm | UL94 | Dry |
Oxygen Index | *** % | ISO 4589 | Dry |
Glow Wire Flammability Index(GWFI) | |||
0.4mm | *** °C | IEC 60695-2-12 | Dry |
0.71mm | *** °C | IEC 60695-2-12 | Dry |
1.5mm | *** °C | IEC 60695-2-12 | Dry |
3mm | *** °C | IEC 60695-2-12 | Dry |
Glow Wire Ignition Test(GWIT) | |||
0.4mm | *** °C | IEC 60695-2-13 | Dry |
0.71mm | *** °C | IEC 60695-2-13 | Dry |
1.5mm | *** °C | IEC 60695-2-13 | Dry |
3.0mm | *** °C | IEC 60695-2-13 | Dry |
| Electrical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Volume Resistivity | *** Ohm-cm | IEC 60093 | Dry, 0.75 mm |
Comparative Tracking Index (CTI) | |||
- | *** V | IEC 60112 | Dry, 3.00 mm |
Dielectric Strength | *** kV/mm | IEC 60243 | Dry, 1.00 mm |
Arc Resistance | *** PLC | ASTM D495 | Dry, 3.00 mm |
High Voltage Arc Tracking Rate(HVTR) | PLC | UL 746 | Dry |
Hot Wire Ignition(HWI) | *** PLC | UL 746 | Dry, 0.40 mm |
Hot Wire Ignition(HWI) | *** PLC | UL 746 | Dry, 0.71 mm |
Hot Wire Ignition(HWI) | *** PLC | UL 746 | Dry, 1.50 mm |
Hot Wire Ignition(HWI) | *** PLC | UL 746 | Dry, 3.00 mm |
High Ampere Arc Ignition(HAI) | *** PLC | UL 746 | Dry, 0.40 mm |
High Ampere Arc Ignition(HAI) | PLC | UL 746 | Dry, 0.71 mm |
High Ampere Arc Ignition(HAI) | PLC | UL 746 | Dry, 1.50 mm |
High Ampere Arc Ignition(HAI) | PLC | UL 746 | Dry, 3.00 mm |
The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.