Processing
Injection Molding
Delivery form
Granules
Special Characteristics
Flame retardant, Improved heat resistance
Regional Availability
North America, Europe, Asia Pacific, South and Central America, Near East/Africa
Product Attributes
Hydrolysis resistant, Improved flowability and demoulding, Improved alcohol resistance, Bio based Polyamide, Co Polyamide, Partially aromatic Polyamide
Automotive
Air intake sytems, Compressed air systems, Hydraulic systems, Automotive electr. and electronics, lighting, Fuel systems, Interior
Electricals & Electronics
Electrical appliances, Electrical equipment, Connectors, Energy distribution, Lighting, Mobile phones and other portable devices
Industry & Consumer goods
Hydraulics & Pneumatics, Mechanical Engineering, Power transmission, Tools & Accessories
Burning Behaviour
UL V0
| Original Document | Technical Datasheet(English) Technical Datasheet(Chinese) | |||
| Features | Heat ResistanceFlame RetardantMold ReleaseBio-basedHydrolysis ResistanceAlcohol ResistantHigh FlowCopolymer | |||
| Additive | Flame RetardantHeat StabilizerHydrolysis Resistant | |||
| Appearance | Pellets/GranulesBlack | |||
| Processing | Injection | |||
| Physical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
|---|---|---|---|
Density/Specific Gravity | *** g/cm³ | ISO 1183 | dry |
Mold Shrinkage | |||
Flow | *** % | ISO 294-4, 2577 | dry |
Across Flow | *** % | ISO 294-4, 2577 | dry |
Water Absorption | *** % | ISO 62 | dry |
Moisture /Humidity Absorption | *** % | ISO 62 | dry |
| Mechanical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Tensile Modulus | *** Mpa | ISO 527-1/-2 | cond. |
Tensile Modulus | *** Mpa | ISO 527-1/-2 | dry |
Tensile Strength | |||
Break | *** Mpa | ISO 527-1/-2 | cond. |
Break | *** Mpa | ISO 527-1/-2 | dry |
Tensile Elongation | |||
Break | *** % | ISO 527-1/-2 | cond. |
Break | *** % | ISO 527-1/-2 | dry |
| Impact | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Charpy Notched Impact Strengh | |||
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eA | cond. |
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eA | dry |
23℃ (73℉) | *** kJ/m² | ISO 179/1eA | cond. |
23℃ (73℉) | *** kJ/m² | ISO 179/1eA | dry |
Charpy Unnotched Impact Strengh | |||
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eU | cond. |
-30℃ (-22℉) | *** kJ/m² | ISO 179/1eU | dry |
23℃ (73℉) | *** kJ/m² | ISO 179/1eU | cond. |
23℃ (73℉) | *** kJ/m² | ISO 179/1eU | dry |
| Hardness | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Ball Indentation Hardness | *** Mpa | ISO 2039-1 | cond. |
Ball Indentation Hardness | *** Mpa | ISO 2039-1 | dry |
| Thermal | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Heat Deflection Temperature(HDT) | |||
0.45 Mpa (66 psi)(4.6kg/cm²) | *** °C | ISO 75-1/-2 | dry |
1.8 Mpa (264 psi)(18.6kg/cm²) | *** °C | ISO 75-1/-2 | dry |
Coefficient of Linear Thermal Expansion | |||
Flow | *** E-6/K | ISO 11359-1/-2 | dry |
Across Flow | *** E-6/K | ISO 11359-1/-2 | dry |
Melt Temperature(Tm) | *** °C | ISO 11357-1/-3 | dry |
Continuous Use Temperature | |||
Long term | *** °C | ISO 2578 | long term |
Temperature at Short Circle Operation | *** °C | Internal | short term |
| Flammability | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Flame Rating | |||
V-0 | *** mm | IEC 60695-11-10 | dry |
V-0 | *** mm | IEC 60695-11-10 | dry |
| Electrical | Value/Unit(Sign in to View) | Test Standard | Test Condition |
Volume Resistivity | *** Ohm-m | IEC 60093 | cond. |
Volume Resistivity | *** Ohm-m | IEC 60093 | dry |
Surface Resistivity | *** Ohm | IEC 60093 | cond. |
Comparative Tracking Index (CTI) | |||
- | *** V | IEC 60112 | cond. |
Dielectric Strength | *** kV/mm | IEC 60243-1 | cond. |
Dielectric Strength | *** kV/mm | IEC 60243-1 | dry |
The information presented on this datasheet was acquired by AjiEng.com from the producer of the material. AjiEng.com makes substantial efforts to assure the accuracy of this data. However, AjiEng.com assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.